Corporate Headquarters:

Staticworx® , Inc.
124 Watertown Street
Watertown, MA 02472

Phone: 617-923-2000
Fax: 617-923-2009

US Mail Address:
PO Box 590069
Newton, MA 02459

Manufacturing and Warehouse:
Staticworx® , Inc.
Hwy 41
Calhoun, Georgia

West Coast Distribution Center:
Los Angeles, California

West Coast Flooring Installation:

Phone: 949-933-0177
Solving ESD flooring problems for over 30 years, StaticWorx (also known as StaticWorks) installs dissipative flooring with proven antistatic capabilities. Call centers, data centers, computer rooms all need the protection provided by anti static vinyl, rubber tile or carpeting.  
 

Ammunition and Explosives ESD Protection Ammunitions and Explosives ESD Flooring RequirementsRequirements from DoD Manual 4145.26-M

The handling and manufacture of ammunition and explosives requires different static protection procedures than those for handling electronic devices. One important document dealing with this type of work is Department of Defense (DoD) manual 4145.26-M, The Contractor’s Safety Manual for Ammunition and Explosives. This document was modified on March 13th, 2008.

You can click here to view section 6.4 from The Contractor's Safety Manual for Ammunition and Explosives (4145.26M) covering static electricity and Grounding.

Here are the essential properties required from a grounded conductive floor used in ammunition and
explosives applications:

The maximum resistance of a body, plus the resistance of the conductive shoes, plus the resistance of the conductive floor to the ground system shall not exceed 1,000,000 ohms total.  (R1 (body) + R2 (shoes) + R3 to ground (Floor ) < 1 million ohms.)

Example: if the floor's resistance to ground is 500,000 ohms then the sum of the resistance of the body plus the resistance of the shoes must be below 500,000 ohms or the total allowable resistance limit of 1,000,000 ohms would be exceeded.

Staticworx® rubber EC flooring meets the ESD requirements of DoD 4145.26-M.

Other applications can include:

Engineering labs, government data centers (National Archives, IRS, SSA, NSA, FBI, etc.), war rooms, communications centers and military base electronics labs.

 

Click here for OSHA Regulations (Standards - 29 CFR), "Explosives and blasting agents. - 1910.109"

Article: Conductive Floors in Naval Hospitals and Ordnance Facilities

Accession Number : ADA033665
Title :   Criteria for Grounding Conductive Floors in Naval Hospitals and Ordnance Facilities.
Descriptive Note : Final rept. Jul 74-Sep 75,
Corporate Author : CIVIL ENGINEERING LAB (NAVY) PORT HUENEME CALIF
Personal Author(s) : Brooks,James L. ; Streets,Barry C.
Report Date : OCT 1976
Pagination or Media Count : 43

Abstract : An investigation of the criteria for grounding conductive floors in Naval hospitals and ordnance facilities has been completed. First, current publications concerned with conductive floor installations were reviewed. Then manufacturers of conductive flooring materials were contacted for the latest technical information available on grounding systems for conductive floors. Finally, a survey was made of existing grounding systems at selected Naval hospitals and ordnance facilities. From this information, design and installation criteria, acceptance testing procedures, and maintenance requirements for conductive flooring installations were developed. (Author)

Descriptors :   *FLOORS, *ELECTRICAL CONDUCTIVITY, *ELECTRICAL GROUNDING, LITERATURE SURVEYS, MUNITIONS INDUSTRY, HOSPITALS, DESIGN CRITERIA, STATIC ELECTRICITY, FLOOR COVERINGS.

Subject Categories : CONSTRUCTION EQUIPMENT, MATERIALS & SUPPLIES
Distribution Statement : APPROVED FOR PUBLIC RELEASE
Search DTIC's Public STINET for similiar documents.

Members of the public may purchase hardcopy documents from the National Technical Information Service.

Purchasing
Government personnel can buy direct from Staticworx® and take advantage
of free shipping within the continental United States by:

1. Call 617-923-2000

2. Email our Federal Sales Director, Dave Long (click name to email)

 

Ammunition and Explosives ESD Protection Requirements from DoD Manual 4145.26-M

headerx topics for static free environments.

 

 

Web Design Company

Solving ESD flooring problems for over 30 years, Staticworx® installs dissipative flooring with proven antistatic capabilities. Call centers, data centers, data centres, computer rooms all need the protection provided by anti static vinyl, rubber tile or carpeting.